Latest Versions
Controller Firmware | DigiTrack Version |
1.1.80 | 9.10.0 |
Minimum Software Requirements
Sensor Type | Controller Firmware Version | Required DigiTrack Version |
Beck Drum | 1.1.42+ | 8.4.6+ |
Beck Drum, Legacy | 1.1.58+ | 9+ |
DF+ Charge Pressure | 1.1.33+ | 8.4.5+ |
DF+ Digital Readout | 1.1.10+ | N/A |
DF+ Discharge Pressure | 1.1.33+ | 8.4.5+ |
DF+ Drum | 1.1.33+ | 8.4.5+ |
DF+/Trimble Washout, Hardwired | 1.1.36+ | 8.4.6+ |
DF+ Washout, CAN (use w/ S Series Flex) |
1.1.55+ (1.1.70+ preferred) |
8.6.1+ |
DF+ Water Control Solenoid | 1.1.21+ | 8.1.1+ |
Eaton Quad Drum | 1.1.33+ | 8.4.5+ |
ELITE Drum and Charge Pressure | 1.1.33+ | 8.4.5+ |
IFM Water Add | 1.1.9+ | 7.7.1+ |
IFM Water Add, Ultra, FR | 1.1.80+ | TBD |
Kimble CyKlone Drum | 1.1.33+ | 8.4.5+ |
Kimble K2200/K2200C Drum | 1.1.33+ | 8.4.5+ |
Kimble K2200/K2200C Charge Pressure | 1.1.33+ | 8.4.5+ |
FLEX Drum and Water | 1.1.33+ | 8.4.5+ |
FLEX Charge Pressure | 1.1.33+ | 8.4.5+ |
RAVEN Charge Pressure | 1.1.33+ | 8.4.5+ |
RAVEN Drum and Water | 1.1.33+ |
8.4.5+ |
S-Series Flex Water |
1.1.54+ (1.1.70+ preferred) |
8.10.1+ |
S-Series Flex Drum | 1.1.43+ | 8.4.6+ |
S-Series Flex Charge Pressure | 1.1.54+ |
8.10.1+ |
S-Series Flex Discharge Pressure | 1.1.54+ |
8.10.1+ |
Maestro Drum | 1.1.47+ | 8.6.1+ |
Trimble Drum | 1.1.33+ | 8.4.5+ |
UFM Water Add (100ppg) | 1.1.56+ |
9.5.0+ |
Trimble Water Add (200ppg) | 1.1.56+ |
9.5.0+ |
Terex Advance Drum | 1.1.40+ |
8.4.6+ |
Terex Advance Drum (Rexroth) | 1.1.80+ |
9.8.0+ |
Terex Advance Charge Pressure | 1.1.40+ |
8.4.6+ |
Terex Charge Pressure (Rexroth) | 1.1.80+ |
9.8.0+ |
Hardware Status V2 | 1.1.44+ |
8.6.0+ |
Regen Messages | 1.1.60+ |
9.10.0+ |
Intake Heater Monitor | 1.1.65+ |
9.8.0+ |
Seat Belt Status | 1.1.70+ |
TBD |
Doran TPMS Trailers | 1.1.70+ |
TBD |
Novotron Drum | 1.1.81+ |
TBD |
Controller Firmware Changelog
version 1.1.80
- Feature: Ultra Flow Meter Support
- Feature: Terex support for Rexroth hydraulic system (fixed bug in 1-1-79)
version 1.1.79 (dev version use 1.1.80+)
- Preliminary Terex Rexroth development
version 1.1.78 (dev version use 1.1.80+)
- Preliminary Ultra flow meter development
version 1.1.77
- Add reset for new decimals counters
version 1.1.76
- Enhance: data streams for volume and drum
version 1.1.75
- Extend water life RX timeout from OSH S Series from 25 seconds to 30 seconds.
version 1.1.74 (dev version use 1.1.75+)
version 1.1.73
- Update TPMS Trailer logic to accommodate for Terex system (V71/72 crash Terex body module)
version 1.1.72 (dev version use 1.1.73+, Do NOT use on Terex)
- S Series dev version
version 1.1.71 (dev version use 1.1.73+, Do NOT use on Terex)
- S Series dev version
version 1.1.70 (dev version use 1.1.73+, Do NOT use on Terex)
- Enhance: S Series 2.0 removes washout water from trip gallon count, the count that gets reported to DigiTrack. (so only reports water added gallons)
- Feature: Pass/bridge the Seat Belt CAN message from the chassis bus to the mixer bus.
- Feature: Pass/bridge the address claim CAN message, used in Doran Trailer TPMS, from the chassis bus to the mixer bus.
- Enhance: S Series 2.0 split water add and washout logic.
version 1.1.69 (dev version use 1.1.70+)
- Enhance: S Series 2.0 split water add and washout logic.
version 1.1.68 (dev version use 1.1.70+)
- Enhance: S Series 2.0 split water add and washout logic.
version 1.1.67
- Enhance: Expand the working range for Quad Direction, as sensor ages, our system will continue to read for longer.
- Enhance: Add diagnostic state for reporting Quad Sensor Direction failure.
version 1.1.66
- Feature: Terex 2023 CAN support for Drum and Slump.
- Feature: New bridge support, this version is required to support the new bridge. DO NOT USE OLDER VERSIONS OF THE HUB FOR THE CR3132 MODEL OF BRIDGE!
version 1.1.65
- Feature: Intake heater monitor.
version 1.1.64
- Enhance: CAN recovery when tablet not seen (on-demand)
-
Enhance: Hub auto rebooting Bridge based on Bluetooth status every 2 minutes of socket disconnection. Add if the tablet is not seen (on-demand) as a condition to trigger bridge reboot.
-
Feature: Battery voltage enum to heartbeat message
version 1.1.63
- Feature: Hub auto rebooting Bridge based on Bluetooth status every 2 minutes of socket disconnection
version 1.1.62
- Feature: Drum Timeout2, ~60 minutes
- Feature: Add IO Status CAN message
- Enhance: Remove brake requirement for VECU status
version 1.1.61
- Feature: Add auto CAN recovery function when tablet not seen
version 1.1.60
- Feature: Add support for new tester tool
version 1.1.59
- Feature: Addition of chassis CAN bridge to include regen messages
version 1.1.58
- Feature: Add Beck Drum Legacy sensor type, uses a different ratio when parsing the drum speed scaled value
version 1.1.57
- Enhance: Update design factor from 1000x to 2000x for quad direction input reading, helps with bad grounding
version 1.1.56
- Enhance: Support the two different types of UFM meters. The Trimble and non-Trimble versions of the meter.
version 1.1.55
- Bugfix: S Series 2.0 Flex Washout
version 1.1.54
- Washout (DF+): update the washout failure condition, how to get a report (sensor status), and washout events function both in ‘ok’ and ‘getting bad’ states.
- Water add (s series flex 2.0): add trip readout (this is needed for driver display in digitrack to readout), make this resettable, create accumulator
- Water add (s series flex 2.0): realign start gallons based on previous end, not on the new “flowing” event start
version 1.1.53
Bugfix/enhance: remove assumption that drum count won't be incremental. Add drum rev count accumulator.
Feature: Pass/bridge the TPMS message (0xFEF4) from the chassis bus to the mixer bus.
version 1.1.52
Bugfix: S-Series Flex (2.0) water add
version 1.1.51
Bugfix: S-Series Flex (2.0) washout not reporting
Enhance: Set hub retain data on initialization
version 1.1.50
Bugfix: S-Series Flex (2.0) drum sensor status
version 1.1.49
Enhance: Accuracy of the UFM water add meter/sensor
Feature: Create our own auto recovery CAN logic, no longer use default semi-auto recovery function
Feature: Maestro auto timeout. Triggers Timeout2 drum error, triggers clear fault message, and clears out stale drum data after ~30 seconds
Enhance: Pass Maestro module messages (SA of x2E) for CAN log visibility
Bug: Add washout sensor status for S Series FLEX when read from CAN
version 1.1.48
Feature: S Series FLEX Washout, read directly from FLEX. (Set washout to Secondary)
version 1.1.47
Enhance: Eaton Maestro drum had different variants of the maestro module.
version 1.1.46
Bugfix: Eaton Maestro drum
version 1.1.45
Feature: Eaton Maestro drum information (drum speed, direction, count)
version 1.1.44
Feature: Discharge lifetime rev count for all configurations
Enhance: Mix count added for Beck, Elite, Raven, and Terex
Enhance: More sensor error states
Requires updated LIB to support changes
version 1.1.43
Bugfix: Oshkosh S-Series FLEX
version 1.1.42
Bugfix: Beck logic does not match what was supplied, made updates to match actual CAN messages.
version 1.1.40
Bugfix: Terex advance CAN trucks 2020 or newer
version 1-1-39
Bugfix: Terex advance CAN trucks 2021 or newer
version 1.1.38
Bugfix: S Series Flex discharge speed. (Comes from a different CAN message than the charge speed does.)
version 1.1.36
Sunset: Remove support for Translator version of the S-Series Flex (only use C14 on connector N2 position 3 and 4)
Sunset: Remove support for Washout switch second location.
Enhance: Bridge FLEX S-Series CAN messages from CAN2 to CAN1, for CAN log
Enhance/bug fix: extend range and add hysteresis to the washout sensor, this prevents the sensor from spamming the system as the sensor deteriorates.
version 1.1.35
Bug Fix: S Series Flex drum direction, reporting charge when paused even if the last state was in discharge, until drum speed reaches 0 RPM.
Feature: S-Series FLEX water add (optional from OEM) to read from CAN
Enhance: S-Series FLEX slump interpretation, based on variable motor slump needs to be taken at Constant Speed and some dynamic adjustments need to be in place
Feature: Refresh/push function via CAN, to be used for baud rate updates, requires a “Reboot” command to follow to clear the baud errors in the module after a baud change.
Bug Fix: Correct real time readout for UFM
version 1.1.33
Feature: Dump truck message (Tarper Sw C3 and Axle Sw C6)
Enhance: Block targets from being set to 0 (25.5 RPM bug)
Bug Fix: Random loss of cyclical messages requiring hub reboot, working with IFM to determine root cause. Mitigation makes all of the ENABLE variables for the CAN_TX_ENH_CYCLIC function block to be TRUE.
Feature: TEREX (preliminary)
Function: Build IEEE 754, single precision function
version 1.1.32
Enhance: Add a parameter for minimum drum speed using DF+ sensors. (was previously hard coded <0.6 rpm).
version 1.1.31
New Software to remove S Series Flex translator module. (Customer will only need to connect C14, backend set to 500k for chassis bus). Add Danny’s message for auto electric water add for digitrack.
version 1.1.30
version 1.1.29
version 1.1.28
version 1.1.27
version 1.1.26
- Bugfix: Kimble K2200 series controls the digital slump meter is an option, so adding a parameter to select the source of the charge pressure (either from CAN or hardwired DF+), “CHARGE_PRESSURE_SOURCE”.
version 1.1.25
- Update logic for Kimble K2200 to use charge pressure threshold to determine drum direction, add hysteresis to this, 100 psi.
- Bugfix: Raven Slump
- Feature: Add “INVERT_DRUM_DIRECTION” for quad sensor direction
version 1.1.24
- Update logic for Kimble K2200 to use charge pressure threshold to determine drum direction
version 1.1.23
- Enhancement to DF+ drum logic
version 1.1.22
- Kimble CyKlone drum rotation bug fix
version 1.1.21
- New features
- Added electronic water control functionality
- Added support for Kimble K2200/K2200C
version 1.1.20
- Kimble Drum
- Fixed bug that prevented accurately determining the Kimble Cyklone drum direction
version 1.1.18
- RAVEN Drum and Water
- Fixed bug that prevented accurately determining the RAVEN drum direction
version 1.1.17
- S Series Flex Drum
- Added support to pull additional data from the S Series Flex Drum
version 1.1.16
- New features
- RAVEN Drum and Water
- Added support for the RAVEN CAN system
- Kimble Drum
- Added support for the Kimble CAN system
- RAVEN Drum and Water
version 1.1.15
- Discharge pressure sensor
- Fixed bug preventing accurate reading of the discharge pressure.
version 1.1.14
- New features
- RAVEN Drum and Water
- Added preliminary support tp read the RAVEN drum speed and water added information.
- RAVEN Drum and Water
version 1.1.13
- CAN status
- Added extra CAN status to heartbeat message
version 1.1.12
- Beck S Series Flex
- Minor updates for Beck S Series Flex
version 1.1.11
- Feature Enhancement
- Washout switch logic updates
version 1.1.10
- New features
- Added Water Trip/Ticket information to the DF+ Display
- Added Booster SKIM module reading
- Quad sensor
- Updated period time base to be able to read speeds down to 0.1 RPM
- Fixed bug preventing reading of drum counts
- Fixed bug preventing proper reading of sensor status
version 1.1.9
- New feature
- Integration for DF+ Digital Readout
Comments
0 comments
Article is closed for comments.